Product Selection Guide

|
|
|
 |
|
 |
 |
Fire Alarm Signal 2 Hour Fire Rated - Shielded
|
|
 |
| 18 GA 2-HOUR FIRE RATED FAS FIRE ALARM |
|
|

CSA CERTIFIED FAS FIRE ALARM CABLE C-UL CLASSIFIED C-UL CLASSIFIED 2-HOUR FIRE RATING PER ULC S-139 WITH HOSE STREAM 300 VOLTS
|
|
APPLICATION:
2-hour fire rated cables for fire alarm systems, communications, and system control where orderly egress or safe shutdowns are essential |
|
DESCRIPTION:
- Solid bare copper - FAS SHIELDED - L.S.Z.H. |
| | | | | | | | | | | | | | | | PART # | | NO. OF CONDUCTORS | | JACKET THICKNESS | | NOMINAL DIAMETER | | NOMINAL WEIGHT | | COLOR CODE | | STD. PUT-UP | | | | | | | | | | | | | | | | | | LIFELINE FAS182S | | 2 | | | | 0.33 in | | 57 lbs/mft | | BLACK/RED NUMBERED | | 305 m | | | | | | | | | | | | | | | | | | LIFELINE FAS184S | | 4 | | | | 0.38 in | | 81 lbs/mft | | BLACK/RED NUMBERED | | 305 m | | | | | | | | | | | | | | | | | | LIFELINE FAS186S | | 6 | | | | 0.44 in | | 110 lbs/mft | | BLACK/RED NUMBERED | | 305 m | | | | | | | | | | | | | | | | | | LIFELINE FAS188S | | 8 | | | | 0.51 in | | 142 lbs/mft | | BLACK/RED NUMBERED | | 305 m | |
|
|
| 16 GA 2-HOUR FIRE RATED FAS FIRE ALARM |
|
|

CSA CERTIFIED FAS FIRE ALARM CABLE C-UL CLASSIFIED C-UL CLASSIFIED 2-HOUR FIRE RATING PER ULC S-139 WITH HOSE STREAM 300 VOLTS
|
|
APPLICATION:
2-hour fire rated cables for fire alarm systems, communications, and system control where orderly egress or safe shutdowns are essential |
|
DESCRIPTION:
- Solid bare copper - FAS SHIELDED - L.S.Z.H. |
| | | | | | | | | | | | | | | | PART # | | NO. OF CONDUCTORS | | JACKET THICKNESS | | NOMINAL DIAMETER | | NOMINAL WEIGHT | | COLOR CODE | | STD. PUT-UP | | | | | | | | | | | | | | | | | | LIFELINE FAS162S | | 2 | | | | 0.35 in | | 66 lbs/mft | | BLACK/RED NUMBERED | | 305 m | | | | | | | | | | | | | | | | | | LIFELINE FAS164S | | 4 | | | | 0.4 in | | 99 lbs/mft | | BLACK/RED NUMBERED | | 305 m | |
|
|
| 14 GA 2-HOUR FIRE RATED FAS FIRE ALARM |
|
|

CSA CERTIFIED FAS FIRE ALARM CABLE C-UL CLASSIFIED C-UL CLASSIFIED 2-HOUR FIRE RATING PER ULC S-139 WITH HOSE STREAM 300 VOLTS
|
|
APPLICATION:
2-hour fire rated cables for fire alarm systems, communications, and system control where orderly egress or safe shutdowns are essential |
|
DESCRIPTION:
- Solid bare copper - FAS SHIELDED - L.S.Z.H. |
| | | | | | | | | | | | | | | | PART # | | NO. OF CONDUCTORS | | JACKET THICKNESS | | NOMINAL DIAMETER | | NOMINAL WEIGHT | | COLOR CODE | | STD. PUT-UP | | | | | | | | | | | | | | | | | | LIFELINE FAS142S | | 2 | | | | 0.4 in | | 85 lbs/mft | | BLACK/RED NUMBERED | | 305 m | | | | | | | | | | | | | | | | | | LIFELINE FAS144S | | 4 | | | | 0.4 in | | 85 lbs/mft | | BLACK/RED NUMBERED | | 305 m | |
|
|
| 12 GA 2-HOUR FIRE RATED FAS FIRE ALARM |
|
|

CSA CERTIFIED FAS FIRE ALARM CABLE C-UL CLASSIFIED C-UL CLASSIFIED 2-HOUR FIRE RATING PER ULC S-139 WITH HOSE STREAM 300 VOLTS
|
|
APPLICATION:
2-hour fire rated cables for fire alarm systems, communications, and system control where orderly egress or safe shutdowns are essential |
|
DESCRIPTION:
- Solid bare copper - FAS SHIELDED - L.S.Z.H. |
| | | | | | | | | | | | | | | | PART # | | NO. OF CONDUCTORS | | JACKET THICKNESS | | NOMINAL DIAMETER | | NOMINAL WEIGHT | | COLOR CODE | | STD. PUT-UP | | | | | | | | | | | | | | | | | | LIFELINE FAS122S | | 2 | | | | 0.42 in | | 101 lbs/mft | | BLACK/RED NUMBERED | | 305 m | | | | | | | | | | | | | | | | | | LIFELINE FAS124S | | 4 | | | | 0.5 in | | 173 lbs/mft | | BLACK/RED NUMBERED | | 305 m | |
|
|
|
|
 |
|